硬盘报警处理方法
通过热插拔的方式来制造故障
注释:
c:Controller,控制器,也就是阵列卡;
e:Enclosure,附件,一般来讲也就是硬盘背板“硬盘笼”;
s:Slot,物理硬盘槽位;
v:Virtual Drive,虚拟硬盘,也就是逻辑卷;
d:Disk Group,硬盘组;
f:Foreign configuration file,外部阵列配置。
蜂鸣器
原主板没有蜂鸣器 自己网上买的有源蜂鸣器焊接上的
查看蜂鸣器
storcli /c0 show alarm
#此时为开启状态
----------------
Ctrl_Prop Value
----------------
Alarm ON
----------------
关闭蜂鸣器(修复完成后 需要重新开启)
storcli /c0 set alarm=off
----------------
Ctrl_Prop Value
----------------
Alarm OFF
----------------
查看控制器
只有一个ctl 为 0 的控制器
storcli show
-------------------------------------------------------------------------------------
Ctl Model Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth
-------------------------------------------------------------------------------------
0 AVAGOMegaRAIDSAS9361-8i 8 4 1 1 1 1 Opt On 1&2 Y 5 NdAtn
-------------------------------------------------------------------------------------
查看阵列下哪块硬盘坏了
storcli /c0/eall/sall show
-----------------------------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
-----------------------------------------------------------------------------------------------------
252:0 8 Onln 0 930.390 GB SATA HDD N N 512B WDC WD10EZEX-08WN4A0 U -
252:1 9 Onln 0 930.390 GB SATA HDD N N 512B WD1003FBYX-88 LEN U -
252:4 17 Onln 0 930.390 GB SATA HDD N N 512B WDC WD10EADX-00TDHB0 U -
252:5 16 UBad - 1.817 TB SATA HDD N N 512B WDC WD20EURX-64H U -
-----------------------------------------------------------------------------------------------------
磁盘状态(State)描述:
UGood(Unconfigured Good,未配置正常):硬盘状态正常,但还未划分给任何逻辑卷;
UBad(Unconfigured Bad,未配置异常):UGood状态的硬盘出现无法恢复的错误;
Onln(Online,在线):已经设置为某个虚拟硬盘的成员盘,并且处于在线正常可用状态;
Offln(Offline,离线):某个虚拟硬盘的成员盘离线;
Missing,Online状态的硬盘脱离RAID组的状态;
Rbld(Rebuild,重建):硬盘正在重建数据。
将252下的5 恢复成UGood 状态
storcli /c0 /e252 /s5 set good
开始重建
storcli /c0 /fall import
-----------------------------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
-----------------------------------------------------------------------------------------------------
252:0 8 Onln 0 930.390 GB SATA HDD N N 512B WDC WD10EZEX-08WN4A0 U -
252:1 9 Onln 0 930.390 GB SATA HDD N N 512B WD1003FBYX-88 LEN U -
252:4 17 Onln 0 930.390 GB SATA HDD N N 512B WDC WD10EADX-00TDHB0 U -
252:5 16 Rbld 0 1.817 TB SATA HDD N N 512B WDC WD20EURX-64HYZY0 U -
-----------------------------------------------------------------------------------------------------
查看重建进度 单个硬盘
storcli /c0 /e252 /s5 show rebuild
------------------------------------------------------
Drive-ID Progress% Status Estimated Time Left
------------------------------------------------------
/c0/e252/s5 7 In progress 2 Hours 25 Minutes
------------------------------------------------------
#需要2个小时25分钟
#当前已经进行了 7%
多个硬盘可以用 /sall
storcli /c0 /e252 /sall show rebuild
----------------------------------------------------------
Drive-ID Progress% Status Estimated Time Left
----------------------------------------------------------
/c0/e252/s0 - Not in progress -
/c0/e252/s1 - Not in progress -
/c0/e252/s4 - Not in progress -
/c0/e252/s5 7 In progress 2 Hours 24 Minutes
----------------------------------------------------------
查看阵列卡温度
storcli /c0 show temperature
# 温度为108度 (我查询到的最高温度......)
--------------------------------------
Ctrl_Prop Value
--------------------------------------
ROC temperature(Degree Celsius) 108
--------------------------------------
查看事件
storcli /c0 show events
seqNum: 0x000360d7
Time: Sat Mar 1 12:45:12 2025
Code: 0x00000067
Class: -1
Locale: 0x02
Event Description: Rebuild progress on PD 10(e0xfc/s5) is 5.8%(486s) ###正在重建 5.8% 已用时486秒
Event Data:
===========
CLI Version = 007.2705.0000.0000 August 24, 2023
Operating system = Linux 6.1.103-1.el9.elrepo.x86_64
Controller = 0
Status = Success
Description = None
Events = GETEVENTS
Controller Properties :
=====================
------------------------------------
Ctrl Status Method Value
------------------------------------
0 Success handleSuboption Events
------------------------------------
查看重建率
storcli /c0 show rebuildrate
------------------
Ctrl_Prop Value
------------------
Rebuildrate 30%
------------------
查询RAID控制卡/RAID组/物理硬盘信息
命令功能
查询RAID控制卡、虚拟磁盘、物理硬盘的详细信息。
命令格式
storcli64 /ccontroller_id show
storcli64 /ccontroller_id/eenclosure_id/sslot_id show all
storcli64 /ccontroller_id/vvd_id show all
参数说明
使用指南
回显中主要字段的含义如表16-32所示。
表16-32 回显说明
使用实例
查询RAID控制卡的详细信息。
storcli /c0 show
Controller = 0
Status = Success
Description = None
Product Name = SAS3408
Serial Number = 024JNFCNK2000314
SAS Address = 58cfd18f55442000
PCI Address = 00:03:00:00
System Time = 07/18/2019 14:55:54
Mfg. Date = 00/00/00
Controller Time = 07/18/2019 06:55:53
FW Package Build = 50.6.3-0109
BIOS Version = 7.06.02.2_0x07060502
FW Version = 5.060.01-2262
Driver Name = megaraid_sas
Driver Version = 07.709.08.00
Vendor Id = 0x1000
Device Id = 0x17
SubVendor Id = 0x19E5
SubDevice Id = 0xD213
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 3
Device Number = 0
Function Number = 0
Drive Groups = 1
TOPOLOGY :
========
---------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
---------------------------------------------------------------------------
0 - - - - RAID0 Optl N 3.637 TB dflt N N dflt N N
0 0 - - - RAID0 Optl N 3.637 TB dflt N N dflt N N
0 0 0 65:0 41 DRIVE Onln N 3.637 TB dflt N N dflt - N
---------------------------------------------------------------------------
DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready
Virtual Drives = 1
VD LIST :
=======
-------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
-------------------------------------------------------------
0/0 RAID0 Optl RW Yes NRWTD - ON 3.637 TB
-------------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
Physical Drives = 39
PD LIST :
=======
------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
------------------------------------------------------------------------------
65:0 41 Onln 0 3.637 TB SATA HDD N N 512B ST4000NM0035-1V4107 U
65:1 45 UGood - 10.912 TB SATA HDD N N 512B ST12000NM0007-2A1101 D
65:2 33 UGood - 10.912 TB SATA HDD N N 512B ST12000NM0007-2A1101 D
65:3 40 UGood - 3.637 TB SATA HDD N N 512B ST4000NM115-1YZ107 D
65:4 39 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:5 38 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:6 46 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:7 53 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:8 61 UGUnsp - 3.637 TB SATA HDD N N 512B ST4000NM0035-1V4107 U
65:9 0 UGood - 3.637 TB SATA HDD N N 512B ST4000NM115-1YZ107 D
65:10 1 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:11 62 UGUnsp - 3.637 TB SATA HDD N N 512B ST4000NM0035-1V4107 U
65:12 51 UGood - 9.094 TB SATA HDD N N 512B ST10000NM0478-2H7100 D
65:13 52 UGood - 10.912 TB SATA HDD N N 512B ST12000NM0007-2A1101 D
65:14 50 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:16 57 UGUnsp - 10.912 TB SATA HDD N N 512B ST12000NM0007-2A1101 U
65:17 58 UGUnsp - 10.912 TB SATA HDD N N 512B ST12000NM0007-2A1101 U
65:18 42 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:19 44 UGood - 10.912 TB SATA HDD N N 512B ST12000NM0007-2A1101 D
65:20 49 UGood - 10.912 TB SATA HDD N N 512B ST12000NM0007-2A1101 D
65:21 43 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:22 48 UGood - 10.912 TB SATA HDD N N 512B ST12000NM0007-2A1101 D
65:23 47 UGood - 3.637 TB SATA HDD N N 512B ST4000NM0035-1V4107 D
65:24 3 UGood - 3.637 TB SATA HDD N N 512B ST4000NM0035-1V4107 D
65:25 5 UGood - 10.912 TB SATA HDD N N 512B ST12000NM0007-2A1101 D
65:26 4 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:27 2 UGood - 3.637 TB SATA HDD N N 512B ST4000NM0035-1V4107 D
65:28 59 UGUnsp - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 U
65:29 6 UGood - 837.258 GB SAS HDD N N 512B ST900MM0168 D
65:30 55 UGood - 3.637 TB SATA HDD N N 512B ST4000NM0035-1V4107 D
65:31 60 UGUnsp - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 U
65:32 56 UGUnsp - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 U
65:33 35 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:34 34 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:35 37 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:36 36 UGood - 5.456 TB SATA HDD N N 512B ST6000NM0115-1YZ110 D
65:37 30 UGood - 278.464 GB SAS HDD N N 512B AL15SEB030N D
65:38 32 UGood - 1.745 TB SATA SSD N N 512B INTEL SSDSC2KG019T8 U
65:39 31 UGood - 222.585 GB SATA SSD N N 512B INTEL SSDSC2KG240G8 U
------------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
查询slot0的物理硬盘的信息。
storcli /c0/e252/s0 show all
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.
Drive /c0/e65/s0 :
================
--------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
--------------------------------------------------------------------------
65:0 41 Onln 0 3.637 TB SATA HDD N N 512B ST4000NM0035-1V4107 U
--------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
Drive /c0/e65/s0 - Detailed Information :
=======================================
Drive /c0/e65/s0 State :
======================
Shield Counter = 0
Media Error Count = 0
Other Error Count = 0
Drive Temperature = 30C (86.00 F)
Predictive Failure Count = 0
S.M.A.R.T alert flagged by drive = No
Drive /c0/e65/s0 Device attributes :
==================================
SN = ZC18JNP4
Manufacturer Id = ATA
Model Number = ST4000NM0035-1V4107
NAND Vendor = NA
WWN = 5000c500b3297aee
Firmware Revision = TNA5
Raw size = 3.638 TB [0x1d1c0beb0 Sectors]
Coerced size = 3.637 TB [0x1d1a94800 Sectors]
Non Coerced size = 3.637 TB [0x1d1b0beb0 Sectors]
Device Speed = 6.0Gb/s
Link Speed = 12.0Gb/s
NCQ setting = Enabled
Write Cache = Disabled
Logical Sector Size = 512B
Physical Sector Size = 512B
Connector Name = C0 & C1
Drive /c0/e65/s0 Policies/Settings :
==================================
Drive position = DriveGroup:0, Span:0, Row:0
Enclosure position = 1
Connected Port Number = 0(path0)
Sequence Number = 2
Commissioned Spare = No
Emergency Spare = No
Last Predictive Failure Event Sequence Number = 0
Successful diagnostics completion on = N/A
SED Capable = No
SED Enabled = No
Secured = No
Cryptographic Erase Capable = No
Locked = No
Needs EKM Attention = No
PI Eligible = No
Certified = Yes
Wide Port Capable = No
Port Information :
================
-----------------------------------------
Port Status Linkspeed SAS address
-----------------------------------------
0 Active 12.0Gb/s 0x500605b000027380
-----------------------------------------
Inquiry Data =
5a 0c ff 3f 37 c8 10 00 00 00 00 00 3f 00 00 00
00 00 00 00 20 20 20 20 20 20 20 20 20 20 20 20
43 5a 38 31 4e 4a 34 50 00 00 00 00 00 00 4e 54
35 41 20 20 20 20 54 53 30 34 30 30 4d 4e 30 30
35 33 31 2d 34 56 30 31 20 37 20 20 20 20 20 20
20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 80
00 40 00 2f 00 40 00 02 00 02 07 00 ff 3f 10 00
3f 00 10 fc fb 00 10 5c ff ff ff 0f 00 00 07 00
查询VD 0的信息。
storcli /c0/v0 show all
Controller = 0
Status = Success
Description = None
/c0/v0 :
======
-------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
-------------------------------------------------------------
0/0 RAID0 Optl RW Yes NRWTD - ON 3.637 TB
-------------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
PDs for VD 0 :
============
--------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
--------------------------------------------------------------------------
65:0 41 Onln 0 3.637 TB SATA HDD N N 512B ST4000NM0035-1V4107 U
--------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
VD0 Properties :
==============
Strip Size = 64 KB
Number of Blocks = 7812499456
VD has Emulated PD = No
Span Depth = 1
Number of Drives Per Span = 1
Write Cache(initial setting) = WriteThrough
Disk Cache Policy = Disk's Default
Encryption = None
Data Protection = None
Active Operations = None
Exposed to OS = Yes
Creation Date = 06-07-2025
Creation Time = 08:44:04 AM
Emulation type = default
Cachebypass size = Cachebypass-64k
Cachebypass Mode = Cachebypass Intelligent
Is LD Ready for OS Requests = Yes
SCSI NAA Id = 68cfd18f554420002ffcf3d4ce5e8046
设置一致性检查参数
命令格式
storcli /c controller_id[/v vd_id]show cc
storcli /c controller_id /v vd_id start cc force
storcli /c controller_id /v vd_id action cc
storcli /c controller_id set cc=conc delay= value starttime= time excludevd= evd_id
参数说明
show命令中不带**/v** vd_id时,表示查询自动CC参数。
show命令中带**/v** vd_id时,表示查询CC进度。
使用实例
查询CC进度。
storcli /c0 show cc
Controller Properties :
=====================
-----------------------------------------------
Ctrl_Prop Value
-----------------------------------------------
CC Operation Mode Concurrent
CC Execution Delay 168 hours
CC Next Starttime 03/08/2025, 03:00:00
CC Current State Stopped
CC Number of iterations 26
CC Number of VD completed 1
CC Excluded VDs None
-----------------------------------------------
设置一致性自动检查参数。
storcli /c0 set cc=conc delay=720 starttime=2025/03/01 23 excludevd=0
Controller = 0
Status = Success
Description = None
Controller Properties :
=====================
------------------------------------
Ctrl_Prop Value
------------------------------------
CC Mode CONC
CC delay 1
CC Starttime 2016/07/14 22:00:00
CC ExcludeVD(0) Success
------------------------------------
查询和设置Patrolread参数
命令格式
storcli /c controller_id set patrolread starttime= time maxconcurrentpd= number
storcli /c controller_id set patrolread delay= delaytime
storcli /c controller_id set patrolread ={on mode=<auto|manual>}|{off}
storcli /c controller_id show patrolread
参数说明
使用实例
查询patrolread信息。
storcli /c0 show patrolread
Controller Properties :
=====================
---------------------------------------------
Ctrl_Prop Value
---------------------------------------------
PR Mode Auto
PR Execution Delay 720 hours
PR iterations completed 29
PR Next Start time 03/01/2025, 23:00:00
PR on SSD Disabled
PR Current State Active 0
PR Excluded VDs None
PR MaxConcurrentPd 255
---------------------------------------------
设置patrolread的起始时间为“2025/03/01 23:00:00”,同时巡检的硬盘数为“2”。
storcli /c0 set patrolread starttime=2025/03/01 23 maxconcurrentpd=2
Controller = 0
Status = Success
Description = None
Controller Properties :
=====================
---------------------------------------
Ctrl_Prop Value
---------------------------------------
PR Starttime 2025/03/01 23:00:00
PR MaxConcurrentPd 2
---------------------------------------
使能patrolread并设置为自动模式。
storcli /c0 set patrolread mode=auto
Controller Properties :
=====================
-----------------------
Ctrl_Prop Value
-----------------------
Patrol Read Mode auto
-----------------------
通过增加新盘扩容或迁移RAID
命令功能
RAID有2种扩容方式:
通过增加成员盘可用容量来扩大RAID容量。
通过增加新硬盘来扩大RAID容量。
下述命令通过增加新硬盘的方式达到RAID扩容的目的。
当增加新盘后,可进行RAID级别迁移。
命令格式
storcli64 /ccontroller_id/vvd_id start migrate type=rlevel option=add drives=enclosure_id:slot_id
参数说明
使用实例
在RAID 5中增加slot 2硬盘扩容。
storcli /c0/v0 start migrate type=r5 option=add drives=252:2
Description = Start VD Operation Success
显示迁移时间和百分比
storcli /c0/v0 show migrate
VD Operation Status :
===================
-------------------------------------------------------
VD Operation Progress% Status Estimated Time Left
-------------------------------------------------------
0 Migrate 0 In progress 17 Hours 3 Minutes
-------------------------------------------------------
单盘RAID 0加盘迁移至RAID 1。
storcli /c0/v0 start migrate type=r0 option=add drives=252:3
Description = Start MIGRATE Operation Success.
查询和设置RAID后台初始化
命令功能
暂停、继续和停止RAID后台初始化,以及查看后台初始化进度。
命令格式
storcli64 /ccontroller_id/vraid_id action bgi
参数说明
以上涉及的各个ID的查询方法请参见查询RAID控制卡/RAID组/物理硬盘信息。
使用实例
# 查看后台初始化进度。
storcli /c0/v0 show bgi
VD Operation Status :
===================
-------------------------------------------------------
VD Operation Progress% Status Estimated Time Left
-------------------------------------------------------
0 BGI 92 In progress 54 Minutes
-------------------------------------------------------
设置后台资源占用率
命令功能
设置后台初始化速率、一致性检查速率、硬盘巡检速率、RAID重构速率、RAID扩容和迁移速率等。
命令格式
storcli64 /c controller_id set action = value
参数说明
使用实例
查看硬盘巡检速率
storcli /c0 show bgirate ccrate prrate rebuildrate reconrate
Controller Properties :
=====================
-----------------------
Ctrl_Prop Value
-----------------------
BGI Rate 50%
CC Rate 50%
Patrol Read Rate 50%
Rebuildrate 30%
ReconRate 80%
-----------------------
storcli /c0 show prrate
Controller Properties :
=====================
-----------------------
Ctrl_Prop Value
-----------------------
Patrol Read Rate 50%
-----------------------
设置硬盘巡检速率为“30%”
storcli /c0 set prrate=30
Controller Properties :
=====================
-----------------------
Ctrl_Prop Value
-----------------------
Patrol Read Rate 30%
-----------------------
定位硬盘
定位第一块RAID上某块物理磁盘,物理磁盘的红色的定位灯会被点亮。
点亮红灯
storcli /c0 /e252 /s7 start locate
关闭红灯
storcli /c0 /e252 /s7 stop locate
设置单个硬盘直通模式
查看是否支持直通模式(JBOD)
storcli /c0 show all | grep -i jbod
Support JBOD = Yes #说明阵列卡支持jbod模式
Support SecurityonJBOD = Yes
Support JBOD Write cache = No
Enable JBOD = No #说明当前关闭jbod模式
开启JBOD
storcli /c0 set jbod=on
评论区